Technical data tables


Technical Data

MATRIX
200 AC/DC

MATRIX
250 AC/DC

MATRIX
400 AC/DC
Three phase input V50/60Hz - 400 400
Single phase input V50/60Hz 230 - -
Installed power KVA 3,8 7 9,4
Fuse (delayed action) A 16 10 16
Open circuit voltage V 54 95 65
Current range A 5÷200 5÷250 5÷400
Duty cycle at (40°C) 100%
60%
X%

A

110
130
200 (30%)
170
200
250 (35%)
250
320
400 (35%)
Standards

IEC 60974-1
EN 50199
S

IEC 60974-1
EN 50199
S

IEC 60974-1
EN 50199
S
Protection Class IP 23 23 23C
Insulation Class F H H
Dimensions mm p
l
h
500
220
425
560
220
425
670
290
525
Weight Kg 18 33 45

Technical Data

AC/DC
260

Single phase input V50Hz

230/400

Installed power KVA

14,4

Fuse A

63/40

Open circuit voltage V

78

Current range A

25÷260

Duty cycle at

100%
60%
X%

A

115
150
195(35%)

Dimensions mm d
w
h

970
405
760

Weight Kg

120


TECHNICAL FEATURES MIGHT CHANGE WITHOUT NOTICE.