Skip to content
MATRIX X HF-R
Arc welding

MATRIX X HF-R

THE ULTIMATE ROBOTIC SOLUTION FOR DC TIG

TIG INVERTER WELDING EQUIPMENT FOR ROBOTIC APPLICATION

MATRIX X series single and three-phase power sources, in the special “R” version, can be easily integrated in TIG welding automated equipment by means of ROBOMAT 1 interface which handles both all the start/stop signals of the process and main welding parameter adjustments.

MATRIX X HF-R

Robomat 01

ROBOMAT01 represents a flexible and efficient interface system that fully meets all Analogic/Digital connections.

Single phase with PFC available

Thanks to PFC the single phase MATRIX X 220 HF optimizes the amount of energy consumption by allowing the use of this
powerful power source with 16 A fuse mains and power generator sets.

Other characteristics

  • TIG DC minimum current from 1A
  • Smart HF IGNITION to grant more accurate and prompter Arc Striking in all conditions
  • Reduced weight and size, easy-to-carry
  • Control rack protection cover
  • Compact water cooling equipment integrable with the power source (optional)
  • Simple automation: TSA1 TIG KIT (Optional)

Available accessories

Discover all available accessories

Configurator
HRX 20
Water cooling equipment HRX 20 230 V
HRX 30

Water cooling equipment HRX 30 400 V

Cea CL-1100

Cea CL-1100 cooling liquid – 5 l Tank

Trolley VT 101

Trolley VT 101 with 2 rolls for power source, cooling equipment and cylinder

Trolley CT 401

Trolley CT 401 with 4 rolls for power source, cooling equipment and cylinder

35 mm² / 4 m Ground cable with clamp

35 mm² / 4 m Ground cable with clamp

A6 kit

A6 Connection kit for non-standard Torch

TSA1 - TIG Simple Automation KIT
TSA1 - TIG Simple Automation KIT - (Torch trigger - Arc On - Current Adj. 0-10V)

Datasheet

MATRIX X HF-R: Technical features

TECHNICAL DATA MATRIX X 220 HF-R MATRIX X 300 HF-R
TIG MMA TIG MMA
Single phase input 50/60 Hz V +20%
-20%
230
Three phase input 50/60 Hz V +20%
-20%
400
Input power @ I2 max kVA 5,2 6,0 8,5 8,5
Delayed Fuse (I2 @ 100%) A 16 16 10 10
Power factor / cos φ 0,99/0,99 0,99/0,99 0,96/0,99 0,95/0,99
Efficiency Degree 0,84 0,87
Open circuit voltage V 85 85
Current range A 1-220 10-180 1-300 10-270
Duty cycle at (40°C) A 100% 160 120 210 200
  A  60% 190 150 250 230
  A X% 220(30%) 180(30%) 300(35%) 270(35%)
Standards EN 60974-1 • EN 60974-3 • EN 60974-10
Protection Class IP 23 S 23 S
Dimensions (LxWxH) mm 530x215x410 530x215x410
Weight kg 18 20

Configurator

Configure MATRIX X HF-R for your needs

Select product
Select product
Water cooling unit
Water cooling accessories
Robotic interface
Robotic accessories
Ground cable
Trolley
Accessories
Select product
Water cooling unit
Water cooling accessories
Robotic interface
Ground cable
Trolley
Accessories